|

|
Zeroing in on your glassware needs.
The most complete tube supplier in the industry is doing more than ever before to meet your replacement needs. In addition to our comprehensive portfolio of CT and X-Ray replacement tubes, we offer an extensive line of Image Intensifiers, High-Voltage Cables, Camera Tubes, and Imaging-Related components. Five additional Dunlee locations provide reliable sales, technical support and customer support.
|  |
|
Please visit the Dunlee website at www.dunlee.com to learn more about Dunlee and our products.
We also have available online the latest technical data specifications and contact information, as well as all the information you need to become one of
Dunlee’s valued customers.
At www.dunlee.com you will find the following and more:
|
- X-Ray and CT Tube Technical DataSpecifications
- Letter of Credit Instructions
- Wire Transfer Instructions
|
Note: Distribution of products may be restricted. Information provided within is subject to change without notice.
Consult Cross Reference Guide for addtional details for products.
Dunlee’s Quality Management System is certified to comply with ISO 13485 for medical devices. Dunlee is approved under EC Directive 93/42/EECAnnex II, Article 3, “Full Quality Assurance System” to CE mark its products. Most of Dunlee’s products are approved to carry the CE mark.All Dunlee manufactured and reloaded products are registered with the FDA (CDRH) via an initial report. Most Dunlee manufactured units areUL classified per UL 187 (X-Ray Equipment), or certified as recognized component per UL 60601-1 Medical Electrical Equipment.
| Dunlee Order Information and Tube Return Policy |
America and Asia Pacific
When placing a tube order, please be ready to specify the tube type, cable terminal angle, and stator type. Applicable published warranty in effect on shipping date will apply.Dunlee reserves the right to make changes to prices and warranty without notice. If a unit needs to be returned for warranty consideration or housing credit, please make sure you do the following:
1) Complete the Tube Return Form with all pertinent information. The Tube Return Form is included in each technical data packet and is also available online atwww.dunlee.com.
2) Fax the completed form to ourCustomer Supportgroup at630.585.2125.
3) Upon receipt of the fax, you will be issued a Return Authorization number. Please reference this number on your copy of the Tube Return Form.
- Ship the product freight prepaid back to Dunlee.
- Please send CT and CV tube returns to Dunlee Aurora at 555 North Commerce Street, Aurora, IL 60504.
- Please send Radiographic tube returns to Dunlee Arlington at 2312 Avenue J, Arlington, TX 76006.
- Please send Image Intensifiers returns to Dunlee-Richmond at 8819 Whitepine Rd. Richmond, VA 23237.
NOTE: For proper receipt of your returned goods, enclose a copy of the Tube Return Form (with Return Authorization number recorded on it) inside the carton with the product! Retain a copy of the Tube Return Form and shipping documentation for your records.
|
Europe, Middle East and Africa
Tubes Returned for Warranty Evaluation or Repair
Ship only prepaid in proper container, insure for full value, and enclose completed Tube Return Form.
New Tubes Returned for Restocking
Ship only prepaid in original container, insure for full value. These new tubes are subject to a 10% of net restocking charge to cover necessary inspection and testing procedures. Complete applicable section(s) of the Tube Return Form and enclose with product.
Housing Credit Only
Ship only prepaid in proper container and enclose completed Tube Return Form.
Returning a product
If a tube or another Dunlee product needs to be returned for housing credit or warranty reasons, please follow these steps:
- Complete thereturn form with all pertinent information. You can request the return form at Dunlee, Düsseldorf or download it from the internet at www.dunlee.eu
- Please ask for a Return Authorization number by phone +49 211 77 05 890 or fax +49 211 20 30 00.
- Fax the completed return form to Dunlee, Düsseldorf to obtain areturn authorization number.
- For proper receipt of your returned goods,enclose a copy of the return form (with return authorization number recorded on it)inside the carton with the product.
- Send the product DDP (prepaid) to our address: Dunlee Medical Components Marbacher Str. 114 40597 Düsseldorf, Germany
- Retain a copy of the return form and shipping documen tation for your records.
|
|
|
| CT Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6-13 |
Elscint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Electric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Philips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Picker/Marconi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Shimadzu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Siemens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Toshiba. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
| Radiographic Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-23 |
PX 1300 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . ..14
PX 1400 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-16
PX 1500 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
DA 10 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
DR 1400 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
General Electric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
Philips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Siemens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Varian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Toshiba. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
| Camera Tubes and Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25 |
Resistron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Saticon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Plumbicon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25
Vidicon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Newvicon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
| CT Cross Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-28 |
| Dunlee Location Listings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 |
|
|
Scanner Manufacturer |
Tube Type |
Ordering No. 9896055 - |
Focal Spot |
Target Angle |
kHU |
Warranty |
| Elscint |
 | This 1.0 MHU CT tube is designed as a replacement for use in Elscint 1800, 2000, and Sprint CT Systems.
Replaces GS-1089 * | - 70610 | 1.3 x 1.6 | 10º | 1,000 | 50K |
| This 1.5 MHU CT tube is designed as a replacement for use with Elscint Select CT Systems.
Replaces GS-1584 * |
- 70510 |
0.8 x 0.9 |
10º |
1,500 |
50K |
 | This 3.5 MHU CT tube is designed as a replacement for use in Elscint Select CT Systems.
Replaces GS-3074 |
- 96603 |
0.8 x 1.2 |
7º |
3,500 |
100K |
 | This 3.5 MHU CT tube is designed as a replacement for use in Elscint Helicat II, Flash and CT Twin II CT Systems.
Replaces GS-3077 |
- 95300
1.5 x 1.5
|
0.8 x 1.5 |
7º |
3,500 |
300K/ss |
 | This 5.0 MHU CT tube is designed as a replacement for use in Elscint Helicat II, Flash and CT Twin II CT Systems.
Replaces GS-5079 * |
- 70110
1.5 x 1.5
|
0.8 x 1.5 |
7º |
5,000 |
300K/ss |
 | This 7.0 MHU CT tube is designed as a replacement for use in Elscint Twin, Flash and RTS CT Systems.
Replaces GS-6079 * |
- 70910
1.5 x 1.5
|
0.8 x 1.5 |
7º |
7,000 |
100K/ss |
| Scanner Manufacturer | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| General Electric |
 |
CT MAX DA/MX 100
This 400 KHU CT tube is designed as a replacement for use in GE CTMAX I, CTMAX II, CTMAX 640, CTMAX 320, and Sytec 1800i systems.
Replaces D3502T/3512T |
- 82700
- 82500
|
0.6 |
6.5º |
400 |
40K |
 |
Sytec Pace DA 115 / MX 115
This 1.5 MHU CT tube is designed as a replacement for use in GE Sytec/Pace CT systems.
Replaces D3302T |
- 83700
- 83500
|
0.7 x 0.4 |
9° |
1,500 |
80K |
 |
HiLight Advantage DA 135 / MX 135
This 2.0 MHU CT tube is designed as a replacement for use in GE HiLight Advantage and 9800 HiLight Advantage CT systems.
Replaces D3302T/3203T |
- 80100
- 80500
|
0.7 x 0.4 |
7° |
2,000 |
80K |
 |
Pegasus DA 135 CT/e / MX 135 CT/e
This 2.0 MHU CT tube is designed as a replacement for use in GE CT/e and CT ProSpeed Ai systems.
Replaces D3162T |
- 80800
- 80801
|
0.7 x 0.6 |
7° |
2,000 |
80K |
 |
Sytec MX 135 Venus SR/i
This 2.0 MHU CT tube is designed as a replacement for use in GE CT systems.
Replaces D3122T |
- 77510 |
0.7 x 0.4 |
7° |
2,000 |
80K |
 |
ProSpeed DA 165PS / MX 165P5
This 3.5 MHU CT tube is designed as a replacemen t for use in GE ProSpeed CT systems.
Replaces D3112T |
- 82901
- 82900
|
0.9 x 0.7 1.2 x 1.2 |
7° |
3,500 |
120K |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| General Electric |
 |
Solarix DA 165NP / MX 165NP
This 3.5 MHU CT tube is designed as a replacement for use in GE HiSpeed FX/i, LX/i, DX/i, and NX/i CT systems
Replaces D3142T
|
- 83901
- 83900
|
0.9 x 0.7
1.2 x 1.2
| 7° | 3,500 | 140K |
 |
HiSpeed DA 165
This 3.5 MHU CT tube is designed as a replacement for use in GE HiSpeed Advantage and GE CT/i CT systems
Replaces D3102T
| - 82600 |
0.9 x 0.7
1.2 x 1.2
| 7° | 6,300 | 140K |
 |
DA 200
This 6.3 MHU CT tube is designed as a replacement for use in GE HiSpeed CT/i
Replaces D3132T
| - 87504 | 0.7 x 0.6
0.9 x 0.9 | 7° | 6,300 | Contact
Dunlee |
|
DA 200
This 6.3 MHU CT tube is designed as a replacement for use in GE LightSpeed QX/i.
Replaces D3176T
| - 87505 | 0.7 x 0.6
0.9 x 0.9 | 7° | 6,300 | Contact
Dunlee |
 |
DA 200 Pro
This 6.3 MHU CT tube is designed as a replacement for use in GE HiSpeed NX/i Pro and HiSpeed ZX/i
Replaces D3152T
| - 88401 | 0.7 x 0.5
0.9 x 0.9 | 7° | 6,300 | Contact
Dunlee |
|
DA 200 ULTRA
This 6.3 MHU CT tube is designed as a replacement for use in GE LightSpeed 16, Discovery ST, Discovery LS, LightSpeed RT, LightSpeed VFX Plus, LightSpeed VFX Ultra and HighSpeed QX/i
Replaces D3182T/D3186T
| - 88704 | 0.7 x 0.6
0.9 x 0.9 | 7° | 6,300 | Contact
Dunlee |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| Philips |
 |
B 180 Philips
DA 180 Philips
This 1.5 MHU CT tube is designed as a replacement for use in Philips Tomoscan CX and TX CT systems. This product replaces OEM insertGS-1580
|
- 82302
- 88500
|
0.8 x 1.5 1.5 x 2.4 |
10° |
1,500 |
50K |
 |
B 220 Philips
DA 220 Philips
This 2.0 MHU CT tube is designed as a replacement for use in Philips Tomoscan SR6000 and LX CT systems. This product replaces OEM insertGS-2070
|
- 82402
- 89500
|
0.7 x 0.8 1.2 x 1.4 |
7° |
2,000 |
50K |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| Picker/Marconi |
 |
CTR 1555RC
CTR 1555RCPN
This 1.5 MHU CT tube is designed as a replacement for use in Picker/Marconi 600 and 1200 CT systems.
|
- 93301
- 82800
|
0.4 x 0.7 0.6 x 1.45 |
10º |
1,500 |
40K |
 |
CTR 1562RC
CTR 1562RCPN
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi 1200 Premier systems. *
|
- 93901
- 81600
|
0.4 x 1.0 0.6 x 1.6 |
10º |
2,000 |
50K |
 |
CTR 1568RC
CTR 1568RCPN
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi IQ, Premier, Xtra, and IQ Xtra T/C (Upgrade) systems. (Used with 50 Hz power.)
|
- 94603
- 82100
|
0.7 x 1.4 |
10º |
2,000 |
50K |
 |
CTR 1569RC
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi IQ, Premier, Xtra, and IQ Xtra T/C (Upgrade) systems. (Used with 60 Hz power.) |
- 94602 |
0.7 x 1.4 |
10º |
2,000 |
50K |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| Picker/Marconi |
Picker/Marconi |
CTR 1563RC
CTR 1563RCPN
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems.
|
- 94701
- 87900
|
0.4 x 0.9 0.6 x 1.45 |
10º |
2,000 |
50K |
 |
CTR 1590RC
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems. * |
- 94707 |
0.4 x 0.9 0.6 x 1.45 |
10º |
2,000 |
80K |
 |
CTR 1762 RGQ
This 3.4 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems. |
- 94803 |
0.4 x 0.7 0.6 x 1.3 |
10º |
3,400 |
50K |
 |
CTR 1791 RGQ
This 4.0 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems. |
- 94809 |
0.4 x 0.7 0.6 x 1.3 |
7º |
4,000 |
80K |
 |
CTR 1790 RGQ
This 5.0 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems. |
- 94807 |
0.4 x 0.7 0.6 x 1.3 |
7º |
5,000 |
100K |
 |
CTR 1792 RGQ
This 6.5 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems. |
- 94811
0.6 x 1.3
|
0.4 x 0.7 |
7º |
6,500 |
120K |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| Shimadzu |
 |
B 180 Shimadzu
DA 180 Shimadzu
This 1.5 MHU CT tube is designed as a replacement for use in Shimadzu systems: SCT3000, SCT4000, SCT5000, SCT4500, and SCT4800 TE. This product replaces OEM insertGS-1585
|
- 82303
- 88600
|
0.8 x 1.5 |
10º |
1,500 |
50K |
 |
B 220 Shimadzu
DA 220 Shimadzu
This 2.0 MHU CT tube is designed as a replacement. for use in Shimadzu series: SCT3000 TX/C, 4000, 5000, 6000, and 7000 CT systems. This product replaces OEM insertGS-2075
|
- 89600
- 82403
|
0.7 x 1.2 1.2 x 1.5 |
7º |
2,000 |
50K |
 |
DA 240 Shimadzu
This 3.5 MHU CT tube is designed as a replacement for use in Shimadzu SCT 6800 series and SCT7000 series CT systems. This product replaces OEM insertGS-3075
|
- 86601 |
0.7 x 1.21.2 x 1.5 |
7º |
3,500 |
100K |
| Siemens |
 |
S 502 Siemens
This 5.3 MHU CT tube is designed as a replacement for use in Siemens Somatom Plus 4 Power and Expert series CT systems.
|
- 95001 |
0.6 x 0.5 0.8 x 1.1 |
7º |
5,300 |
130 kss |
| Scanner ManufacturerElscint | Tube Type | Ordering No. 9896055 - | Focal Spot | Target Angle | kHU | Warranty |
| Toshiba |
 |
B 180 Toshiba
DA 180 Toshiba
This 1.5 MHU CT tube is designed as a replacement for use in these Toshiba series: TCT80A, TCT300, TCT400, and TCT500 CT systems. This product replaces OEM insertGS-1588
|
- 88200
- 82301
|
1.0 x 1.0 |
10º |
1,500 |
50K |
 |
B 220 Toshiba
DA 220 Toshiba
This 2.0 MHU CT tube is designed as a replacement for use in Toshiba series: Xspeed, 600S, XT, and HQ CT systems. This product replaces OEM insertGS-2078
|
- 89200
- 82401
|
0.9 x 0.9 1.1 x 1.0 |
7º |
2,000 |
50K |
 |
DA 240 Toshiba
This 3.5 MHU CT tube is designed as a replacement for use in Toshiba TCT 900SX series, Xvision, and Xpress series CT systems. |
- 86602 |
1.1 x 1.1 1.7 x 1.7 |
7º |
3,500 |
100K |
| Radiographic Tubes - 3 in / 76mm Anode Unit - PX 1300 Series |

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
|
|
Ordering No. 9896055 |
Horn Angle |
Stator Type |
Focal Spot |
Target Angle |
kW Rating |
kVp |
Anode Storage Capacity kHU |
| Radiographic Tubes - 140 kHU |
|
PX 1351 |
- 91501
- 91503
- 91502
|
C E G |
S
S
S
|
1.0/2.0 |
16° |
23/49 |
125 |
140 |
| Radiographic Tubes - 300 kHU |
|
PX 1302 |
- 91542
- 91537
- 91546
- 91538
|
A
C
D
E
|
S
S
S
S
|
1.0/2.0 |
15° |
37/78 |
150 |
300 |
|
PX 1312 |
- 91514
- 91516
- 91518
|
A
C
E
|
S
S
|
0.6/1.2
S
|
12.5° |
27/70 |
150 |
300 |
| Radiographic Tubes - 4 in / 100mm Anode Unit - PX 1400 Series |

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
|
| Ordering No. 9896055 | Horn Angle | Stator Type | Focal Spot | Target Angle | kW Rating | kVp | Anode Storage Capacity kHU |
| Radiographic Tubes - 300 kHU |
|
PX 1402 |
- 91610
- 91611
- 91615
- 91612
- 91613
- 91614
|
C
E
G
C
E
G
|
S
S
S
Q
Q
Q
| 1.0/2.0 | 15° | 60/120 | 150 | 300 |
| Radiographic Tubes - 300 kHU |
| PX 1429 |
- 94208
- 94204
- 94214
- 94205
- 94206
- 94209
- 94210
- 94213
- 94211
- 94212
|
A
C
D
E
G
A
C
D
E
G
|
S
S
S
S
S
Q
Q
Q
Q
Q
| 0.6/1.2 | 13.5° | 40/100 | 150 | 300 |
| Radiographic Tubes - 400 kHU |
| PX 1436 | -
- 93014
- 93017
- 93015
- 93039
- 93005
- 93007
- 93016
- 93011
|
C
D
E
G
A
C
D
E
|
S
S
S
S
Q
Q
Q
Q
| 0.6/1.2 | 13.5° | 40/100 | 150 | 400 |
|
PX 1482 |
- 92604
- 92606
- 92603
- 92601
- 92605
|
A
C
G
A
C
|
S
S
S
Q
Q
|
0.6/1.0 |
15° |
25/60 |
150 |
400 |
|
PX 1483 |
- 92804
- 92803
- 92801
- 92805
|
A
G
A
C
|
S
S
Q
Q
|
0.3/1.0 |
15° |
9/60 |
150 |
400 |
| Radiographic Tubes - 4 in / 100mm Anode Unit - PX 1400 Series |
Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
|
| Ordering No. 9896055 | Horn Angle | Stator Type | Focal Spot | Target Angle | kW Rating | kVp | Anode Storage Capacity kHU |
| Radiographic Tubes - 300 kHU |
|
PX 1463Radiographic Tubes 600 kHU |
- 94101
- 94102
- 94103
- 94104
- 94105
- 94106
- 94107
- 94108
- 94109
- 94110
|
A
C
D
E
G
A
C
D
E
G
|
S
S
S
S
S
Q
Q
Q
Q
Q
| 1.0/2.0 | 12° | 60/120 | 150 | 600 |
|
PX 1492 |
- 91572 |
C |
S |
0.6/1.2 |
12° |
40/100 |
150 |
600 |
|
PX 1494 |
- 91573 |
C |
S |
0.4/0.8 |
14° |
15/45 |
150 |
600 |
| Radiographic Tubes - 300 kHU |
| PX 1475 |
- 94900 |
C |
S |
0.6/1.2 |
12° |
29/83 |
150 |
750 |
| Radiographic Tubes - 300 kHU |
PX 1558 *
 |
- 93110
- 93111
- 93113
- 93119
|
G
H
G
G
|
QMI
Q
Q
QMP
|
0.3/1.0 |
12.5° |
44/120 |
150 |
1,000 |

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
|
| Ordering No. 9896055 | Horn Angle | Stator Type | Focal Spot | Target Angle | kW Rating | kVp | Anode Storage Capacity kHU |
| Radiographic Tubes - 300 kHU |
|
DA 1002 |
- 80210 |
C |
R |
1.0/2.0 |
15° |
60/120 |
150 |
300 |
|
DA 1029 |
- 80220 |
C |
R |
0.6/1.2 |
13.5° |
40/100 |
150 |
300 |
| Radiographic Tubes - 400 kHU |
|
DA 1036 |
- 80310 |
C |
R |
0.6/1.2 |
13.5° |
40/100 |
150 |
400 |
|
DA 1082 |
- 80320 |
C |
R |
0.6/1.0 |
15° |
25/60 |
150 |
400 |
|
DA 1083 |
- 80330 |
C |
R |
0.3/1.0 |
15° |
9/60 |
150 |
400 |
| Radiographic Tubes - 600 kHU |
|
DA 1092 |
- 80920
- 75620
|
C
E
|
R
R
|
0.6/1.2 |
12° |
40/100 |
150 |
600 |
|
DA 1094 |
- 80930 |
C |
R |
0.4/0.8 |
14° |
15/45 |
150 |
600 |
| Radiographic Tubes - 4 in / 100mm Anode Unit - DA 10 Series |

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
|
| Ordering No. 9896055 | Horn Angle | Stator Type | Focal Spot | Target Angle | kW Rating | kVp | kHU |
| Radiographic Tubes - 300 kHU |
| DA 1429 | - 96101 | C | R | 0.6/1.2 | 13.5° | 40/100 | 150 | 300 |
| Radiographic Tubes - 400 kHU |
| DA 1436 | - 96111 | C | R | 0.6/1.2 | 13.5° | 40/100 | 150 | 400 |
| Radiographic Tubes - 600 kHU |
| DA 1492 | - 96121 | C | R | 0.6/1.2 | 12° | 40/100 | 150 | 600 |
|
DR 1494 |
- 96131 |
C |
R |
0.4/0.8 |
14° |
15/45 |
150 |
600 |

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.
| Ordering No.9896055 | Horn Angle | Pressure
Switch | FocalSpot | TargetAngle | kHU | kVp
|
|
General Electric |
|
AMX 3 |
- 87429 |
C |
No |
0.75 |
15° |
300 |
130 |
|
AMX 4 |
- 86702 |
C |
Yes |
0.75 |
15° |
300 |
130 |
MX 100 * |
- 87383
- 87384
- 87385
- 87386
|
C
C
E
E
|
No
Yes
No
Yes
|
0.6/1.25 |
13.5° |
400 |
150 |
MX 100FLX * |
- 87388
- 87387
|
A
A
|
No
Yes
|
0.6/1.25 |
13.5° |
400 |
150 |
| Ordering No.9896055 | Horn Angle | Pressure
Switch | FocalSpot | TargetAngle | kHU | kVp
|
| General Electric |
|
GE-HRT * |
- 87217 |
C | | |