ГлавнаяКаталогВакансии Контакты

Каталог:


Наши проекты:

Cайт paritet-moscow.ru носит информационный характер и не является публичной офертой, определяемой положениями Статьи 437 ГК РФ.
Для получения подробной информации обращайтесь в филиалы компании Паритет.


Рентгеновские трубки DUNLEE
 

 

About Dunlee...

 

 

Zeroing in on your glassware needs.

The most complete tube supplier in the industry is doing more than ever before to meet your replacement needs. In addition to our comprehensive portfolio of CT and X-Ray replacement tubes, we offer an extensive line of Image Intensifiers, High-Voltage Cables, Camera Tubes, and Imaging-Related components. Five additional Dunlee locations provide reliable sales, technical support and customer support.

Please visit the Dunlee website at www.dunlee.com to learn more about Dunlee and our products.
We also have available online the latest technical data specifications and contact information, as well as all the information you need to become one of
Dunlee’s valued customers.
At www.dunlee.com you will find the following and more:
  • X-Ray and CT Tube Technical DataSpecifications
  • Customer Application
  • Credit Application
  • Letter of Credit Instructions
  • Wire Transfer Instructions
  • Tube Return Form

Note: Distribution of products may be restricted. Information provided within is subject to change without notice.

Consult Cross Reference Guide for addtional details for products.

Dunlee’s Quality Management System is certified to comply with ISO 13485 for medical devices. Dunlee is approved under EC Directive 93/42/EECAnnex II, Article 3, “Full Quality Assurance System” to CE mark its products. Most of Dunlee’s products are approved to carry the CE mark.All Dunlee manufactured and reloaded products are registered with the FDA (CDRH) via an initial report. Most Dunlee manufactured units areUL classified per UL 187 (X-Ray Equipment), or certified as recognized component per UL 60601-1 Medical Electrical Equipment.

 

Dunlee Order Information and Tube Return Policy

 

America and Asia Pacific

When placing a tube order, please be ready to specify the tube type, cable terminal angle, and stator type. Applicable published warranty in effect on shipping date will apply.Dunlee reserves the right to make changes to prices and warranty without notice. If a unit needs to be returned for warranty consideration or housing credit, please make sure you do the following:

1) Complete the Tube Return Form with all pertinent information. The Tube Return Form is included in each technical data packet and is also available online atwww.dunlee.com.

2) Fax the completed form to ourCustomer Supportgroup at630.585.2125.

3) Upon receipt of the fax, you will be issued a Return Authorization number. Please reference this number on your copy of the Tube Return Form.

- Ship the product freight prepaid back to Dunlee.

- Please send CT and CV tube returns to Dunlee Aurora at 555 North Commerce Street, Aurora, IL 60504.

- Please send Radiographic tube returns to Dunlee Arlington at 2312 Avenue J, Arlington, TX 76006.

- Please send Image Intensifiers returns to Dunlee-Richmond at 8819 Whitepine Rd. Richmond, VA 23237.

NOTE: For proper receipt of your returned goods, enclose a copy of the Tube Return Form (with Return Authorization number recorded on it) inside the carton with the product! Retain a copy of the Tube Return Form and shipping documentation for your records.

Europe, Middle East and Africa

Tubes Returned for Warranty Evaluation or Repair

Ship only prepaid in proper container, insure for full value, and enclose completed Tube Return Form.

New Tubes Returned for Restocking

Ship only prepaid in original container, insure for full value. These new tubes are subject to a 10% of net restocking charge to cover necessary inspection and testing procedures. Complete applicable section(s) of the Tube Return Form and enclose with product.

Housing Credit Only

Ship only prepaid in proper container and enclose completed Tube Return Form.

Returning a product

If a tube or another Dunlee product needs to be returned for housing credit or warranty reasons, please follow these steps:

  • Complete thereturn form with all pertinent information. You can request the return form at Dunlee, Düsseldorf or download it from the internet at www.dunlee.eu
  • Please ask for a Return Authorization number by phone +49 211 77 05 890 or fax +49 211 20 30 00.
  • Fax the completed return form to Dunlee, Düsseldorf to obtain areturn authorization number.
  • For proper receipt of your returned goods,enclose a copy of the return form (with return authorization number recorded on it)inside the carton with the product.
  • Send the product DDP (prepaid) to our address: Dunlee Medical Components Marbacher Str. 114 40597 Düsseldorf, Germany
  • Retain a copy of the return form and shipping documen tation for your records.

 

 
 

 

 

CT Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6-13

 

 

Elscint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

General Electric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

Philips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Picker/Marconi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11

Shimadzu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Siemens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Toshiba. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Radiographic Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-23

 

 

PX 1300 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . ..14

PX 1400 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-16

PX 1500 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

DA 10 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

DR 1400 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

General Electric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20

Philips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Siemens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Varian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23

Toshiba. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Camera Tubes and Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25

 

 

Resistron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Saticon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Plumbicon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25

Vidicon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Newvicon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

CT Cross Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-28

 

Dunlee Location Listings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

 

 

 

 

Scanner Manufacturer Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Elscint
This 1.0 MHU CT tube is designed as a replacement for use in Elscint 1800, 2000, and Sprint CT Systems.
Replaces GS-1089 *
- 706101.3 x 1.610º1,00050K
This 1.5 MHU CT tube is designed as a replacement for use with Elscint Select CT Systems.
Replaces GS-1584 *
- 70510 0.8 x 0.9 10º 1,500 50K
This 3.5 MHU CT tube is designed as a replacement for use in Elscint Select CT Systems.
Replaces GS-3074
- 96603 0.8 x 1.2 7º 3,500 100K
This 3.5 MHU CT tube is designed as a replacement for use in Elscint Helicat II, Flash and CT Twin II CT Systems.
Replaces GS-3077

- 95300

1.5 x 1.5

0.8 x 1.5 7º 3,500 300K/ss
This 5.0 MHU CT tube is designed as a replacement for use in Elscint Helicat II, Flash and CT Twin II CT Systems.
Replaces GS-5079 *

- 70110

1.5 x 1.5

0.8 x 1.5 7º 5,000 300K/ss
This 7.0 MHU CT tube is designed as a replacement for use in Elscint Twin, Flash and RTS CT Systems.
Replaces GS-6079 *

- 70910

1.5 x 1.5

0.8 x 1.5 7º 7,000 100K/ss

 

 

Scanner Manufacturer Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
General Electric
CT MAX DA/MX 100
This 400 KHU CT tube is designed as a replacement for use in GE CTMAX I, CTMAX II, CTMAX 640, CTMAX 320, and Sytec 1800i systems.
Replaces D3502T/3512T

- 82700

- 82500

0.6 6.5º 400 40K
Sytec Pace DA 115 / MX 115
This 1.5 MHU CT tube is designed as a replacement for use in GE Sytec/Pace CT systems. Replaces D3302T

- 83700

- 83500

0.7 x 0.4 9° 1,500 80K
HiLight Advantage DA 135 / MX 135
This 2.0 MHU CT tube is designed as a replacement for use in GE HiLight Advantage and 9800 HiLight Advantage CT systems.
Replaces D3302T/3203T

- 80100

- 80500

0.7 x 0.4 7° 2,000 80K
Pegasus DA 135 CT/e / MX 135 CT/e
This 2.0 MHU CT tube is designed as a replacement for use in GE CT/e and CT ProSpeed Ai systems.
Replaces D3162T

- 80800

- 80801

0.7 x 0.6 7° 2,000 80K
Sytec MX 135 Venus SR/i
This 2.0 MHU CT tube is designed as a replacement for use in GE CT systems.
Replaces D3122T
- 77510 0.7 x 0.4 7° 2,000 80K
ProSpeed DA 165PS / MX 165P5
This 3.5 MHU CT tube is designed as a replacemen t for use in GE ProSpeed CT systems.
Replaces D3112T

- 82901

- 82900

0.9 x 0.7 1.2 x 1.2 7° 3,500 120K

 

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
General Electric

Solarix DA 165NP / MX 165NP


This 3.5 MHU CT tube is designed as a replacement for use in GE HiSpeed FX/i, LX/i, DX/i, and NX/i CT systems


Replaces D3142T

- 83901

- 83900

0.9 x 0.7

1.2 x 1.2

7°3,500140K

HiSpeed DA 165


This 3.5 MHU CT tube is designed as a replacement for use in GE HiSpeed Advantage and GE CT/i CT systems


Replaces D3102T

- 82600

0.9 x 0.7

1.2 x 1.2

7°6,300140K

DA 200


This 6.3 MHU CT tube is designed as a replacement for use in GE HiSpeed CT/i


Replaces D3132T

- 875040.7 x 0.6
0.9 x 0.9
7°6,300Contact
Dunlee

DA 200


This 6.3 MHU CT tube is designed as a replacement for use in GE LightSpeed QX/i.


Replaces D3176T

- 875050.7 x 0.6
0.9 x 0.9
7°6,300Contact
Dunlee

DA 200 Pro


This 6.3 MHU CT tube is designed as a replacement for use in GE HiSpeed NX/i Pro and HiSpeed ZX/i


Replaces D3152T

- 884010.7 x 0.5
0.9 x 0.9
7°6,300Contact
Dunlee

DA 200 ULTRA


This 6.3 MHU CT tube is designed as a replacement for use in GE LightSpeed 16, Discovery ST, Discovery LS, LightSpeed RT, LightSpeed VFX Plus, LightSpeed VFX Ultra and HighSpeed QX/i


Replaces D3182T/D3186T

- 887040.7 x 0.6
0.9 x 0.9
7°6,300Contact
Dunlee

 

 

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Philips

B 180 Philips

DA 180 Philips


This 1.5 MHU CT tube is designed as a replacement for use in Philips Tomoscan CX and TX CT systems. This product replaces OEM insertGS-1580

- 82302

- 88500

0.8 x 1.5 1.5 x 2.4 10° 1,500 50K

B 220 Philips

DA 220 Philips


This 2.0 MHU CT tube is designed as a replacement for use in Philips Tomoscan SR6000 and LX CT systems. This product replaces OEM insertGS-2070

- 82402

- 89500

0.7 x 0.8 1.2 x 1.4 7° 2,000 50K

 

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Picker/Marconi

CTR 1555RC

CTR 1555RCPN

This 1.5 MHU CT tube is designed as a replacement for use in Picker/Marconi 600 and 1200 CT systems.

- 93301

- 82800

0.4 x 0.7 0.6 x 1.45 10º 1,500 40K

CTR 1562RC

CTR 1562RCPN

This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi 1200 Premier systems. *

- 93901

- 81600

0.4 x 1.0 0.6 x 1.6 10º 2,000 50K

CTR 1568RC

CTR 1568RCPN

This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi IQ, Premier, Xtra, and IQ Xtra T/C (Upgrade) systems. (Used with 50 Hz power.)

- 94603

- 82100

0.7 x 1.4 10º 2,000 50K
CTR 1569RC
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi IQ, Premier, Xtra, and IQ Xtra T/C (Upgrade) systems. (Used with 60 Hz power.)
- 94602 0.7 x 1.4 10º 2,000 50K

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Picker/Marconi
Picker/Marconi

CTR 1563RC

CTR 1563RCPN

This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems.

- 94701

- 87900

0.4 x 0.9 0.6 x 1.45 10º 2,000 50K
CTR 1590RC
This 2.0 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems. *
- 94707 0.4 x 0.9 0.6 x 1.45 10º 2,000 80K
CTR 1762 RGQ
This 3.4 MHU CT tube is designed as a replacement for use in Picker/Marconi PQ CT systems.
- 94803 0.4 x 0.7 0.6 x 1.3 10º 3,400 50K
CTR 1791 RGQ
This 4.0 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems.
- 94809 0.4 x 0.7 0.6 x 1.3 7º 4,000 80K
CTR 1790 RGQ
This 5.0 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems.
- 94807 0.4 x 0.7 0.6 x 1.3 7º 5,000 100K
CTR 1792 RGQ
This 6.5 MHU CT tube is designed as a replacement for use with Picker/Marconi PQ CT systems.

- 94811

0.6 x 1.3

0.4 x 0.7 7º 6,500 120K

 

 

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Shimadzu

B 180 Shimadzu

DA 180 Shimadzu

This 1.5 MHU CT tube is designed as a replacement for use in Shimadzu systems: SCT3000, SCT4000, SCT5000, SCT4500, and SCT4800 TE. This product replaces OEM insertGS-1585

- 82303

- 88600

0.8 x 1.5 10º 1,500 50K

B 220 Shimadzu

DA 220 Shimadzu

This 2.0 MHU CT tube is designed as a replacement. for use in Shimadzu series: SCT3000 TX/C, 4000, 5000, 6000, and 7000 CT systems. This product replaces OEM insertGS-2075

- 89600

- 82403

0.7 x 1.2 1.2 x 1.5 7º 2,000 50K

DA 240 Shimadzu

This 3.5 MHU CT tube is designed as a replacement for use in Shimadzu SCT 6800 series and SCT7000 series CT systems. This product replaces OEM insertGS-3075

- 86601 0.7 x 1.21.2 x 1.5 7º 3,500 100K
Siemens

S 502 Siemens

This 5.3 MHU CT tube is designed as a replacement for use in Siemens Somatom Plus 4 Power and Expert series CT systems.

- 95001 0.6 x 0.5 0.8 x 1.1 7º 5,300 130 kss

 

Scanner ManufacturerElscint Tube Type Ordering No. 9896055 - Focal Spot Target Angle kHU Warranty
Toshiba

B 180 Toshiba

DA 180 Toshiba

This 1.5 MHU CT tube is designed as a replacement for use in these Toshiba series: TCT80A, TCT300, TCT400, and TCT500 CT systems. This product replaces OEM insertGS-1588

- 88200

- 82301

1.0 x 1.0 10º 1,500 50K

B 220 Toshiba

DA 220 Toshiba

This 2.0 MHU CT tube is designed as a replacement for use in Toshiba series: Xspeed, 600S, XT, and HQ CT systems. This product replaces OEM insertGS-2078

- 89200

- 82401

0.9 x 0.9 1.1 x 1.0 7º 2,000 50K
DA 240 Toshiba
This 3.5 MHU CT tube is designed as a replacement for use in Toshiba TCT 900SX series, Xvision, and Xpress series CT systems.
- 86602 1.1 x 1.1 1.7 x 1.7 7º 3,500 100K

 

Radiographic Tubes - 3 in / 76mm Anode Unit - PX 1300 Series

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

Ordering No. 9896055 Horn Angle Stator Type Focal Spot Target Angle kW Rating kVp Anode Storage Capacity kHU
Radiographic Tubes - 140 kHU
PX 1351

- 91501

- 91503

- 91502

C E G

S

S

S

1.0/2.0 16° 23/49 125 140
Radiographic Tubes - 300 kHU
PX 1302

- 91542

- 91537

- 91546

- 91538

A

C

D

E

S

S

S

S

1.0/2.0 15° 37/78 150 300
PX 1312

- 91514

- 91516

- 91518

A

C

E

S

S

0.6/1.2

 

S

12.5° 27/70 150 300

 

Radiographic Tubes - 4 in / 100mm Anode Unit - PX 1400 Series

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

 

Ordering No. 9896055 Horn Angle Stator Type Focal Spot Target Angle kW Rating kVp Anode Storage Capacity kHU
Radiographic Tubes - 300 kHU
PX 1402

- 91610

- 91611

- 91615

- 91612

- 91613

- 91614

C

E

G

C

E

G

S

S

S

Q

Q

Q

1.0/2.015°60/120150300
Radiographic Tubes - 300 kHU
PX 1429

- 94208

- 94204

- 94214

- 94205

- 94206

- 94209

- 94210

- 94213

- 94211

- 94212

A

C

D

E

G

A

C

D

E

G

S

S

S

S

S

Q

Q

Q

Q

Q

0.6/1.213.5°40/100150300
Radiographic Tubes - 400 kHU
PX 1436 -

- 93014

- 93017

- 93015

- 93039

- 93005

- 93007

- 93016

- 93011

C

D

E

G

A

C

D

E

S

S

S

S

Q

Q

Q

Q

0.6/1.213.5°40/100150400
PX 1482

- 92604

- 92606

- 92603

- 92601

- 92605

A

C

G

A

C

S

S

S

Q

Q

0.6/1.0 15° 25/60 150 400
PX 1483

- 92804

- 92803

- 92801

- 92805

A

G

A

C

S

S

Q

Q

0.3/1.0 15° 9/60 150 400

 

Radiographic Tubes - 4 in / 100mm Anode Unit - PX 1400 Series

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

 

Ordering No. 9896055 Horn Angle Stator Type Focal Spot Target Angle kW Rating kVp Anode Storage Capacity kHU
Radiographic Tubes - 300 kHU
PX 1463Radiographic Tubes 600 kHU

- 94101

- 94102

- 94103

- 94104

- 94105

- 94106

- 94107

- 94108

- 94109

- 94110

A

C

D

E

G

A

C

D

E

G

S

S

S

S

S

Q

Q

Q

Q

Q

1.0/2.012°60/120150600
PX 1492 - 91572 C S 0.6/1.2 12° 40/100 150 600
PX 1494 - 91573 C S 0.4/0.8 14° 15/45 150 600
Radiographic Tubes - 300 kHU
PX 1475 - 94900 C S 0.6/1.2 12° 29/83 150 750
Radiographic Tubes - 300 kHU
PX 1558 *

- 93110

- 93111

- 93113

- 93119

G

H

G

G

QMI

Q

Q

QMP

0.3/1.0 12.5° 44/120 150 1,000

 

About Dunlee...

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

 

Ordering No. 9896055 Horn Angle Stator Type Focal Spot Target Angle kW Rating kVp Anode Storage Capacity kHU
Radiographic Tubes - 300 kHU
DA 1002 - 80210 C R 1.0/2.0 15° 60/120 150 300
DA 1029 - 80220 C R 0.6/1.2 13.5° 40/100 150 300
Radiographic Tubes - 400 kHU
DA 1036 - 80310 C R 0.6/1.2 13.5° 40/100 150 400
DA 1082 - 80320 C R 0.6/1.0 15° 25/60 150 400
DA 1083 - 80330 C R 0.3/1.0 15° 9/60 150 400
Radiographic Tubes - 600 kHU
DA 1092

- 80920

- 75620

C

E

R

R

0.6/1.2 12° 40/100 150 600
DA 1094 - 80930 C R 0.4/0.8 14° 15/45 150 600

 

Radiographic Tubes - 4 in / 100mm Anode Unit - DA 10 Series

 

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

 

Ordering No. 9896055 Horn Angle Stator Type Focal Spot Target Angle kW Rating kVp kHU
Radiographic Tubes - 300 kHU
DA 1429 - 96101CR0.6/1.213.5°40/100150300
Radiographic Tubes - 400 kHU
DA 1436 - 96111CR0.6/1.213.5°40/100150400
Radiographic Tubes - 600 kHU
DA 1492 - 96121CR0.6/1.212°40/100150600
DR 1494 - 96131 C R 0.4/0.8 14° 15/45 150 600

 

Radiographic Tubes | GE

 

Radiographic tubes designed for general radiographic light-duty/heavy-duty X-Ray systems.

 

Ordering No.9896055Horn AnglePressure
Switch
FocalSpotTargetAnglekHUkVp
General Electric
AMX 3 - 87429 C No 0.75 15° 300 130
AMX 4 - 86702 C Yes 0.75 15° 300 130
MX 100 *

- 87383

- 87384

- 87385

- 87386

C

C

E

E

No

Yes

No

Yes

0.6/1.25 13.5° 400 150
MX 100FLX *

- 87388

- 87387

A

A

No

Yes

0.6/1.25 13.5° 400 150
Radiographic Tubes | GE

 

 

Ordering No.9896055Horn AnglePressure
Switch
FocalSpotTargetAnglekHUkVp
General Electric
GE-HRT * - 87217 C